DELL硬件监控(omreport)

时间:2024-03-06 13:15:12

DELL硬件监控(omreport)

omreport: omsa报告

显示已经安装的硬件设备的数字许可证(就是显示idrac的一些信息)
./omreport licenses

Licenses information

Device Index       : 0
Device Status      : Ok
Device             : iDRAC
Device Description : iDRAC8
Device ID          : 25F6YM2
License Index      : 0
Description        : iDRAC8 Enterprise License
Status             : OK
Recommended Action : N/A
License Type       : Perpetual
Entitlement ID     : FD00000010160082
Expiry Date        : N/A

报告系统偏好信息的配置(在这里我们公司是没有进行配置的所以都是空)
./omreport preferences

  • 事件日志
    这里的都是日志,不是硬件的实时状态
    ./omreport system alertlog
Alert Log

Alert Log contains...

Severity      : Critical # 状态  # 就像这个就说明在A11的内存位置上有位错误
ID            : 1404 # 事件id
Date and Time : Mon Aug 12 14:26:00 2019 # 事件发生的时间
Category      : Instrumentation Service
Description   : Memory device status is critical # 说明
Memory device location: A11  # 设备位置
Possible memory module event cause:Multi bit error encountered # 问题说明

Severity      : Ok
ID            : 2415
Date and Time : Sun Dec 15 20:15:06 2019
Category      : Storage Service
Description   : Controller battery is discharging:  Battery 0 Controller 0

Severity      : Ok
ID            : 2243
Date and Time : Sat Dec 14 12:58:00 2019
Category      : Storage Service
Description   : The Patrol Read has stopped.:  Controller 0 (PERC H730 Mini)

Severity      : Ok
ID            : 2242
Date and Time : Sat Dec 14 11:00:54 2019
Category      : Storage Service
Description   : The Patrol Read has started.:  Controller 0 (PERC H730 Mini)

Severity      : Ok
ID            : 2243
Date and Time : Sat Dec  7 13:20:27 2019
Category      : Storage Service
Description   : The Patrol Read has stopped.:  Controller 0 (PERC H730 Mini)

Severity      : Ok
ID            : 2242
Date and Time : Sat Dec  7 11:00:53 2019
Category      : Storage Service
Description   : The Patrol Read has started.:  Controller 0 (PERC H730 Mini)


Severity      : Ok
ID            : 1000
Date and Time : Mon Aug 12 14:23:39 2019
Category      : Instrumentation Service
Description   : Server Administrator starting

Severity      : Ok
ID            : 1012
Date and Time : Mon Aug 12 14:23:39 2019
Category      : Instrumentation Service
Description   : IPMI status
Interface: OS

Severity      : Ok
ID            : 1001
Date and Time : Mon Aug 12 14:23:39 2019
Category      : Instrumentation Service
Description   : Server Administrator startup complete
  • 资产信息展示
    ./omreport system assetinfo
Summary of Asset Information

-------------
Acquisition
-------------
Purchase Cost                                : 0
Reference to Delivery Slip number (Way Bill) : 0
Reference to PO number                       : 0
Who Signed for                               : Please set the value
Installation Date                            : Please set the value
Purchase Date                                : Please set the value
Vendor                                       : Dell
Expensed                                     : Yes
Cost Center                                  : Please set the value

--------------
Depreciation
--------------
Method                                       : Please set the value
Duration                                     : 0
Duration Unit Type                           : Months
Percentage                                   : 0

-------------------
Extended Warranty
-------------------
Cost                                         : 0
Provider                                     : Please set the value
Start Date                                   : Please set the value
End Date                                     : Please set the value

-------
Lease
-------
Multiple Schedules                           : No
Buyout Amount                                : 0
Rate Factor                                  : 0
End Date                                     : Please set the value
Fair Market Value                            : 0
Lessor                                       : Please set the value

-------------
Maintenance
-------------
Provider                                     : Please set the value
Restrictions                                 : Please set the value
Start Date                                   : Please set the value
End Date                                     : Please set the value

-----------
Outsource
-----------
Problem Component                            : Please set the value
Service Fee                                  : Please set the value
Who Signed for                               : Please set the value
Provider Fee                                 : Please set the value
SLA Level                                    : Please set the value

---------
Support
---------
Outsourced                                   : No
Type                                         : Network
Help Desk                                    : Please set the value
Automatic Fix                                : Please set the value

------------------
Service Contract
------------------
Renewed                                      : No
Type                                         : Please set the value
Vendor                                       : Please set the value

----------
Warranty
----------
Duration                                     : 0
Unit Type                                    : Days
End Date                                     : Please set the value
Cost                                         : 0

--------
System
--------
System Bootup Time                           : Mon Mar 11 17:58:40 2019
System Time                                  : Tue Feb  4 19:07:32 2020
System Name                                  : node28.blistack.ops.beta.bj1.wormpex.com
System Location                              : Please set the value
Primary User Name                            : Please set the value
Primary User Telephone Number                : Please set the value

-------
Owner
-------
Type                                         : Owned
Owner Name                                   : Please set the value
Insurance Company                            : Please set the value

嵌入式日志管理系统日志展示
这里的信息和下图的信息是一致的
67bb6991.png

./omreport system esmlog

Embedded System Management (ESM) Log

Health : Ok

Severity      : Ok
Date and Time : Fri Jul 20 19:07:11 2018
Description   : Log cleared.

Severity      : Non-Critical
Date and Time : Wed Aug  1 11:00:14 2018
Description   : Correctable memory error rate exceeded for DIMM_B7.

Severity      : Critical
Date and Time : Wed Aug  1 11:00:40 2018
Description   : Correctable memory error rate exceeded for DIMM_B7.
.....
  • 显示该设备的基础信息
    ./omreport system summary
System Summary

------------------
Software Profile
------------------
Systems Management   # 这下边的信息是omsa的软件版本信息
Name                       : Dell OpenManage Server Administrator
Version                    : 8.2.0
Description                : Systems Management Software
Contains                   : Data Engine 8.2.0
                           : Data Engine SNMP 8.2.0
                           : Disney SNMP 8.2.0
                           : Hardware Abstraction Programming Interface 8.2.0
                           : Instrumentation Services 8.2.0
                           : Meta package for installing the Server Administrator Storage Services feature 8.2.0
                           : Meta package for installing the Server Administrator storage cli component 8.2.0
                           : Meta package for installing the Server Administrator storage snmp component 8.2.0
                           : Meta package for installing the Server Agent 8.2.0
                           : NVMe Library 8.2.0
                           : OpenManage Inventory Collector 8.2.0
                           : RealSSD package for storage management 8.2.0
                           : Remote Access Card Data Populator 8.2.0
                           : Server Administrator CLI 8.2.0
                           : Server Administrator Common Framework 8.2.0
                           : Server Administrator Common Services 8.2.0
                           : Server Administrator Core 8.2.0
                           : Server Administrator XML Support SDK 8.2.0
                           : Storage Management CLI component 5.2.0
                           : Storage Management SNMP component 5.2.0
                           : Storage Management System Utilities Package / Libsysfs 1.3.0
                           : Storage Management accessors package 5.2.0
                           : Storage Management common files for GUI and CLI 5.2.0
                           : StoreLib package for storage management 8.2.0
                           : System Utilities Package/Libsysfs for LSI storage libraries 2.1.0
                           : iDRAC SNMP components 8.2.0

Operating System
Name                       : CentOS Linux
Version                    : release 7.4.1708 (Core)  Kernel 3.10.0-693.el7.x86_64 (x86_64)
System Time                : Tue Feb  4 19:13:42 2020
System Bootup Time         : Mon Mar 11 17:58:40 2019

--------
System
--------
System
Host Name                  : node28.blistack.ops.beta.bj1.wormpex.com  # 这个是主机名
System Location            : Please set the value
Lifecycle Controller       : Enabled

---------------------
Main System Chassis
---------------------
Chassis Information 
Chassis Model              : PowerEdge R730 # 型号
Chassis Service Tag        : 25F6YM2 # sn号 
Express Service Code       : 4681414586 # 快速服务代码
Chassis Lock               : Present
Chassis Asset Tag          : Unknown
Node Id                    : 25F6YM2  # sn号

Remote Access Information
Remote Access Device       : iDRAC8 Enterprise
vFlash Media               : Absent

# cpu相关的信息
Processor 1
Processor Brand            : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Processor Version          : Model 79 Stepping 1
Voltage                    : 1300 mV

Processor 2
Processor Brand            : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Processor Version          : Model 79 Stepping 1
Voltage                    : 1300 mV

# 内存相关的信息
Memory
Total Installed Capacity   : 393216  MB
Memory Available to the OS : 386690  MB
Total Maximum Capacity     : 3145728  MB
Memory Array Count         : 1

Memory Array 1
Location                   : System Board or Motherboard
Use                        : System Memory
Installed Capacity         : 393216  MB
Maximum Capacity           : 2097152  MB
Slots Available            : 24
Slots Used                 : 24
ECC Type                   : Multibit ECC

# pci插槽相关信息
Slot PCIe Slot 1
Adapter                    : [Not Occupied]
Type                       : PCI E Gen 3 X16
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

Slot PCIe Slot 2
Adapter                    : [Not Occupied]
Type                       : PCI E Gen 3 X16
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

Slot PCIe Slot 3
Adapter                    : [Not Occupied]
Type                       : PCI E Gen 3 X16
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

Slot PCIe Slot 4
Adapter                    : [Not Occupied]
Type                       : PCI E Gen 3
Data Bus Width             : 16x or x16
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

Slot PCIe Slot 5
Adapter                    : Intel(R) 10GbE 2P X520 Adapter
Type                       : PCI E Gen 3 X16
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

Slot PCIe Slot 6
Adapter                    : [Not Occupied]
Type                       : PCI E Gen 3 X16
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

Slot PCIe Slot 7
Adapter                    : [Not Occupied]
Type                       : PCI E Gen 3 X16
Data Bus Width             : 8x or x8
Speed                      : [Not Obtained, see card documentation]
Slot Length                : Long
Voltage Supply             : 3.3 Volts

# bios信息其实就是版本

BIOS Information
Manufacturer               : Dell Inc.
Version                    : 2.9.1
Release Date               : 12/04/2018

# idrac相关信息其实就是版本号
Firmware Information
Name                       : iDRAC8
Version                    : 2.50.50.50 (Build 33)

Firmware Information
Name                       : Lifecycle Controller
Version                    : 2.50.50.50

# ipmi配置的地址网关
--------------------------
Remote Access Controller
--------------------------
Remote Access Controller Information
Product                    : iDRAC8 Enterprise
IP Address                 : 10.252.200.11
IP Subnet                  : 255.255.255.0
IP Gateway                 : 10.252.200.254
IPv6 Address 1             : ::
IPv6 Address 2             : ::
IPv6 Gateway               : ::

# 机器上的网卡的基本信息

--------------
Network Data
--------------
Network Interface 0
IP Address                 : [No Value]
MAC Address                : 80:18:44:F0:EA:9C

Network Interface 1
IP Address                 : [No Value]
MAC Address                : 80:18:44:F0:EA:9D

Network Interface 2
IP Address                 : [No Value]
MAC Address                : 80:18:44:F0:EA:9E

Network Interface 3
IP Address                 : [No Value]
MAC Address                : 80:18:44:F0:EA:9F

Network Interface 4
IP Address                 : [No Value]
MAC Address                : B4:96:91:1F:8F:90

Network Interface 5
IP Address                 : [No Value]
MAC Address                : B4:96:91:1F:8F:92

Team Interface 0
IP Address                 : [No Value]
MAC Address                : B4:96:91:1F:8F:90

Team Interface 1
IP Address                 : [No Value]
MAC Address                : D6:A9:1A:D4:4A:4A

Team Interface 2
IP Address                 : [No Value]
MAC Address                : 0A:3E:97:8F:21:89

Team Interface 3
IP Address                 : 10.253.200.11
Subnet Mask                : 255.255.255.192
Default Gateway            : 10.253.200.62
MAC Address                : 7E:14:9E:9D:45:A0

--------------------
Storage Enclosures
--------------------
Storage Enclosures
Name                       : Backplane
  • 电源监控相关输出
    一般的服务的电源都是双电源
    ./omreport chassis pwrmonitoring
Power Consumption Information

Power Consumption
Index             : 2
Status            : Ok  # 这里是状态
Probe Name        : System Board Pwr Consumption
Reading           : 294 W # 这里是当前的渎职
Warning Threshold : 896 W # 这个是警告的阈值,可以通过omconfig进行修改
Failure Threshold : 980 W # 这个是故障的阈值,可以通过omconfig进行修改

Amperage # 俩个电源当前的消费A数
PS1 Current 1 : 1.4 A
PS2 Current 2 : 0.2 A

Power Headroom
System Instantaneous Headroom : 595 W
System Peak Headroom          : 534 W

Power Tracking Statistics # 这个是从统计开始时间到统计结束时间所使用的电源总计
Statistic               : Energy Consumption
Measurement Start Time  : Sun Dec 24 15:04:00 2017
Measurement Finish Time : Tue Feb  4 19:22:14 2020
Reading                 : 4528.2 kWh

Statistic              : System Peak Power # 这里统计了使用的峰值w
Measurement Start Time : Sun Dec 24 15:04:01 2017
Peak Time              : Tue Feb  4 16:18:39 2020
Peak Reading           : 366 W

Statistic              : System Peak Amperage # 使用的峰值 A
Measurement Start Time : Sun Dec 24 15:04:01 2017
Peak Time              : Thu Sep 19 15:37:05 2019
Peak Reading           : 2.2 A
  • 输出当前的bios的配置
    ./omreport chassis biossetup

Operation is under progress, it may take few seconds to complete...

Note: use display=shortnames optional parameter to see attribute names and setting values in short form.
BIOS Setup


System Information
------------------------------------------
System Model Name                                   : PowerEdge R730
System BIOS Version                                 : 2.9.1
System Management Engine Version                    : 3.1.3.38
System Service Tag                                  : 25F6YM2
System Manufacturer                                 : Dell Inc.
System Manufacturer Contact Information             : www.dell.com
System CPLD Version                                 : 1.0.1
UEFI Compliance Version                             : 2.4

Memory Settings
------------------------------------------
System Memory Size                                  : 384 GB
System Memory Type                                  : ECC DDR4
System Memory Speed                                 : 1866 Mhz
System Memory Voltage                               : 1.20 V
Video Memory                                        : 16 MB
System Memory Testing                               : Disabled
Memory Operating Mode                               : Optimizer Mode
Node Interleaving                                   : Disabled
Snoop Mode                                          : Opportunistic Snoop Broadcast
Correctable Memory ECC SMI                          : Enabled

Processor Settings
------------------------------------------
Logical Processor                                   : Enabled
QPI Speed                                           : Maximum data rate
QPI Link L1 Power Management                        : Enabled
Alternate RTID (Requestor Transaction ID) Setting   : Disabled
Virtualization Technology                           : Enabled
Address Translation Services (ATS)                  : Enabled
Adjacent Cache Line Prefetch                        : Enabled
Hardware Prefetcher                                 : Enabled
DCU Streamer Prefetcher                             : Enabled
DCU IP Prefetcher                                   : Enabled
Execute Disable                                     : Enabled
Logical Processor Idling                            : Disabled
Configurable TDP                                    : Nominal
X2Apic Mode                                         : Disabled
Dell Controlled Turbo                               : Disabled
Number of Cores per Processor                       : All
Processor 64-bit Support                            : Yes
Processor Core Speed                                : 2.20 GHz
Processor Bus Speed                                 : 8.0 GT/s
Family-Model-Stepping                               : 6-4F-1
Brand                                               : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Level 2 Cache                                       : 10x256 KB
Level 3 Cache                                       : 25 MB
Number of Cores                                     : 10
Microcode                                           : 0xB000033
Family-Model-Stepping                               : 6-4F-1
Brand                                               : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Level 2 Cache                                       : 10x256 KB
Level 3 Cache                                       : 25 MB
Number of Cores                                     : 10
Microcode                                           : 0xB000033

SATA Settings
------------------------------------------
Embedded SATA                                       : AHCI Mode
Security Freeze Lock                                : Enabled
Write Cache                                         : Disabled
Port A                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port B                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port C                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port D                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port E                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port F                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port G                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port H                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port I                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A
Port J                                              : Auto
Model                                               : Unknown
Drive Type                                          : Unknown Device
Capacity                                            : N/A

Boot Settings
------------------------------------------
Boot Mode                                           : BIOS
Boot Sequence Retry                                 : Enabled
Hard-Disk Failover                                  : Disabled

    BIOS Boot Settings
    ------------------------------------------

    Boot Sequence
                                                    : 0. Enabled: Hard drive C:
                                                    : 1. Enabled: NIC in Slot 5 Port 1 Partition 1: IBA XE Slot 0600 v2390
                                                    : 2. Enabled: NIC in Slot 5 Port 2 Partition 1: IBA XE Slot 0601 v2390

    Hard-Disk Drive Sequence
                                                    : 0. Integrated RAID Controller 1: PERC H730 Mini(bus 03 dev 00)

    One-Time Boot
    ------------------------------------------
    One-Time Boot Device List                       : Disabled
    BIOS Boot Sequence Device                       : NIC in Slot 5 Port 1 Partition 1: IBA XE Slot 0600 v2390
    BIOS Hard-Disk Drive Sequence Device            : Integrated RAID Controller 1: PERC H730 Mini(bus 03 dev 00)

Integrated Devices
------------------------------------------
USB 3.0 Setting                                     : Disabled
User Accessible USB Ports                           : All Ports On
Internal USB Port                                   : On
Integrated RAID Controller                          : Enabled
Integrated Network Card 1                           : Enabled
Integrated Network Card 1 Port 1 Boot Protocol      : None
Integrated Network Card 1 Port 2 Boot Protocol      : None
Integrated Network Card 1 Port 3 Boot Protocol      : None
Integrated Network Card 1 Port 4 Boot Protocol      : None
I/OAT DMA Engine                                    : Disabled
I/O Non-Posted Prefetch                             : Enabled
I/O Snoop HoldOff Response                          : 256 Cycles
Embedded Video Controller                           : Enabled
Current State of Embedded Video Controller          : Enabled
SR-IOV Global Enable                                : Disabled
OS Watchdog Timer                                   : Disabled
Memory Mapped I/O above 4GB                         : Enabled
Lower Memory Mapped I/O Base to 512G                : Disabled

    Slot Disablement
    ------------------------------------------
    Global Slot Boot Driver Disable                 : Disabled
    Slot 1                                          : Enabled
    Slot 2                                          : Enabled
    Slot 3                                          : Enabled
    Slot 4                                          : Enabled
    Slot 5                                          : Enabled
    Slot 6                                          : Enabled
    Slot 7                                          : Enabled

    Slot Bifurcation
    ------------------------------------------
    Slot 1 Bifurcation                              : Default Bifurcation
    Slot 2 Bifurcation                              : Default Bifurcation
    Slot 3 Bifurcation                              : Default Bifurcation
    Slot 4 Bifurcation                              : Default Bifurcation
    Slot 5 Bifurcation                              : Default Bifurcation
    Slot 6 Bifurcation                              : Default Bifurcation
    Slot 7 Bifurcation                              : Default Bifurcation

Serial Communication
------------------------------------------
Serial Communication                                : Auto
Serial Port Address                                 : Serial Device1=COM2,Serial Device2=COM1
External Serial Connector                           : Serial Device 1
Failsafe Baud Rate                                  : 115200
Remote Terminal Type                                : VT100/VT220
Redirection After Boot                              : Enabled

System Profile Settings
------------------------------------------
System Profile                                      : Performance
CPU Power Management                                : Maximum Performance
Memory Frequency                                    : Maximum Performance
Turbo Boost                                         : Enabled
Energy Efficient Turbo                              : Disabled
C1E                                                 : Disabled
C States                                            : Disabled
Write Data CRC                                      : Disabled
Collaborative CPU Performance Control               : Disabled
Memory Patrol Scrub                                 : Standard
Memory Refresh Rate                                 : 1x
Uncore Frequency                                    : Maximum
Energy Efficient Policy                             : Performance
Number of Turbo Boost Enabled Cores for Processor 1 : All
Number of Turbo Boost Enabled Cores for Processor 2 : All
Monitor/Mwait                                       : Enabled
Workload Profile                                    : Not Available
Power Saver                                         : Disabled

System Security
------------------------------------------
Intel(R) AES-NI                                     : Enabled
System Password                                     :
Setup Password                                      :
Password Status                                     : Unlocked
    TPM Information                                 : No TPM present
    TPM Status                                      : Unknown
Intel(R) TXT                                        : Off
AC Power Recovery                                   : Last
AC Power Recovery Delay                             : Immediate
User Defined Delay (60s to 240s)                    : 60
UEFI Variable Access                                : Standard
Secure Boot                                         : Disabled
Secure Boot Policy                                  : Standard

Miscellaneous Settings
------------------------------------------
Asset Tag                                           :
Keyboard NumLock                                    : On
F1/F2 Prompt on Error                               : Enabled
Load Legacy Video Option ROM                        : Disabled
In-System Characterization                          : Disabled
  • bmc相关信息输出
    ./omreport chassis bmc
Remote Access Information

Remote Access Device
Device Type                        : iDRAC8 Enterprise
iDRAC Ports                        : Present
IPMI Version                       : 2.0
System GUID                        : 324d594f-c0b2-3680-4610-00354c4c4544
Number of Possible Active Sessions : 5
Number of Current Active Sessions  : 0
Enable IPMI Over LAN               : Yes
SOL Enabled                        : Yes
MAC Address                        : 50-9A-4C-79-96-BD

IPv4 Address
IP Address Source : Static
IP Address        : 10.252.200.11
IP Subnet         : 255.255.255.0
IP Gateway        : 10.252.200.254

  • 风扇详细信息
    ./omreport chassis fans
Index                     : 5 # id
Status                    : Ok # 状态,这个状态是根据报警阈值进行区分的
Probe Name                : System Board Fan6 # 风扇名称
Reading                   : 4560 RPM # 当前的读取值
Minimum Warning Threshold : 600 RPM # 警告报警值
Maximum Warning Threshold : [N/A]
Minimum Failure Threshold : 360 RPM # 故障报警值
Maximum Failure Threshold : [N/A]
  • 传感器有插槽详细信息
    ./omreport chassis fru
System Components (FRU) Information

# 管理卡设备
Device           : System Planar (iDRAC8)
Serial No.       : CNWS3007C4000G
Part No.         : 0WCJNT
Revision         : A08
Manufacturer     : DELL
Manufacture Date : Tue Dec 05 07:08:00 2017

# 电源设备
Device           : Power Supply 1 (PS1)
Serial No.       : PHARP007A600ZD
Part No.         : 0PJMDN
Revision         : A01
Manufacturer     : DELL
Manufacture Date : Fri Oct 06 15:30:00 2017


Device           : Power Supply 2 (PS2)
Serial No.       : PHARP007A600ZB
Part No.         : 0PJMDN
Revision         : A01
Manufacturer     : DELL
Manufacture Date : Fri Oct 06 15:29:00 2017

Device           : Disk Drive Bay (BP1)
Serial No.       : CNFCP007BM00AI
Part No.         : 07K5HK
Revision         : A01
Manufacturer     : DELL
Manufacture Date : Thu Nov 30 09:59:00 2017

Device           : Add-in Card (NDC)
Serial No.       : CN7361479T04LP
Part No.         : 0FM487
Revision         : A06
Manufacturer     : DELL
Manufacture Date : Sat Sep 29 00:00:00 2007

Device           : Add-in Card (PERC1)
Serial No.       : CNFCP007BN02H8
Part No.         : 0KMCCD
Revision         : A08
Manufacturer     : DELL
Manufacture Date : Fri Nov 24 17:43:00 2017

Device           : A1
Serial No.       : 2B3DC481
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017

Device           : A2
Serial No.       : 2B3DC670
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017

Device           : A3
Serial No.       : 2B3DC565
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017

Device           : A4
Serial No.       : 2B3DC63A
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017

Device           : A5
Serial No.       : 2B3DC6AB
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017

Device           : A6
Serial No.       : 2B3DC417
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017

Device           : A7
Serial No.       : 2B3DC648
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017

Device           : A8
Serial No.       : 2B3DC55F
Part No.         : HMA82GR7AFR8N-UH
Revision         : N/A
Manufacturer     : Hynix Semiconductor (00AD00B300AD)
Manufacture Date : Mon Dec 11 20:00:00 2017
  • 内存详细信息
    ./omreport chassis memory
Index          : 23 # id
Status         : Ok # 状态
Connector Name : B12 # 槽位
Type           : DDR4 - Synchronous Registered (Buffered)
Size           : 16384  MB # 大小
  • 网络接口卡详细信息
    ./omreport chassis nics
Network Interfaces Information

# 物理接口
Physical NIC Interface(s)
Index             : 0
Interface Name    : eth0 # 接口名称
Vendor            : Broadcom Corporation
Description       : NetXtreme BCM5720 Gigabit Ethernet PCIe
Connection Status : Disabled
Slot              : Embedded
...

# 虚拟接口
Team Interface(s)
Index             : 0
Interface Name    : br-bond0
Vendor            : CentOS Linux
Description       : Virtual Switch
Redundancy Status : Not Applicable
...
  • 端口属性信息
    ./omreport chassis ports
Port Type      : USB
External Name  : Front USB port 2
Base I/O Addr  :
IRQ Lvl        :
Connector Type : Access Bus (USB)
Maximum Speed  :
  • 处理器信息
    ./omreport chassis processors

Health : Ok

Index             : 0 # id
Status            : Ok # 健康状态
Connector Name    : CPU1 # 名称 
Processor Brand   : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz # 型号
Processor Version : Model 79 Stepping 1
Current Speed     : 2200  MHz 
State             : Present
Core Count        : 10

Index             : 1
Status            : Ok
Connector Name    : CPU2
Processor Brand   : Intel(R) Xeon(R) CPU E5-2630 v4 @ 2.20GHz
Processor Version : Model 79 Stepping 1
Current Speed     : 2200  MHz
State             : Present
Core Count        : 10
  • 电源状态信息
    ./omreport chassis pwrsupplies
Power Supplies Information

Power Supply Redundancy
Redundancy Status : Full

Individual Power Supply Elements
Index                    : 0 # id 
Status                   : Ok # 状态
Location                 : PS1 Status # 位置
Type                     : AC
Rated Input Wattage      : 900 W # 输入
Maximum Output Wattage   : 750 W # 输出
Firmware Version         : 00.1B.53
Online Status            : Presence Detected # 线上状态
Power Monitoring Capable : Yes

Index                    : 1
Status                   : Ok
Location                 : PS2 Status
Type                     : AC
Rated Input Wattage      : 900 W
Maximum Output Wattage   : 750 W
Firmware Version         : 00.1B.53
Online Status            : Presence Detected
Power Monitoring Capable : Yes
  • pci插槽状态
    ./omreport chassis slots
Slots Information
这里可以看到slots的状态

Index          : 0
Slot ID        : PCIe Slot 1 # 插槽id
Adapter        : [Not Occupied]
Data Bus Width : 8x or x8 # 就像这个是总线插槽大小

Index          : 3
Slot ID        : PCIe Slot 4
Adapter        : [Not Occupied]
Data Bus Width : 16x or x16

Index          : 4 # 就像是这个就是查了一个万兆网卡
Slot ID        : PCIe Slot 5
Adapter        : Intel(R) 10GbE 2P X520 Adapter
Data Bus Width : 8x or x8

Index          : 5
Slot ID        : PCIe Slot 6
Adapter        : [Not Occupied]
Data Bus Width : 8x or x8

Index          : 6
Slot ID        : PCIe Slot 7
Adapter        : [Not Occupied]
Data Bus Width : 8x or x8

Index          : 7  # 这个是插来 千兆网卡
Slot ID        : Embedded
Adapter        : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A

Index          : 8
Slot ID        : Embedded
Adapter        : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A

Index          : 9
Slot ID        : Embedded
Adapter        : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A

Index          : 10
Slot ID        : Embedded
Adapter        : NetXtreme BCM5720 Gigabit Ethernet PCIe
Data Bus Width : N/A

Index          : 11
Slot ID        : Embedded
Adapter        : PERC H730 Mini
Data Bus Width : N/A

Index          : 12
Slot ID        : Embedded
Adapter        : G200eR2
Data Bus Width : N/A

Index          : 13 # usb的设备
Slot ID        : Embedded
Adapter        : C610/X99 series chipset USB Enhanced Host Controller #1
Data Bus Width : N/A

Index          : 14
Slot ID        : Embedded
Adapter        : C610/X99 series chipset USB Enhanced Host Controller #2
Data Bus Width : N/A
  • 系统主要的温度相关的数据
    ./omreport chassis temps
Temperature Probes Information

------------------------------------
Main System Chassis Temperatures: Ok
------------------------------------

Index                     : 0
Status                    : Ok
Probe Name                : System Board Inlet Temp # 指标的名称
Reading                   : 26.0 C # 当前的读取的值
Minimum Warning Threshold : 3.0 C # 这里就是报警的阈值可以使用omconfig修改
Maximum Warning Threshold : 42.0 C
Minimum Failure Threshold : -7.0 C
Maximum Failure Threshold : 47.0 C

Index                     : 1
Status                    : Ok
Probe Name                : System Board Exhaust Temp
Reading                   : 38.0 C
Minimum Warning Threshold : 0.0 C
Maximum Warning Threshold : 70.0 C
Minimum Failure Threshold : 0.0 C
Maximum Failure Threshold : 75.0 C

Index                     : 2
Status                    : Ok
Probe Name                : CPU1 Temp
Reading                   : 45.0 C
Minimum Warning Threshold : 8.0 C
Maximum Warning Threshold : 85.0 C
Minimum Failure Threshold : 3.0 C
Maximum Failure Threshold : 90.0 C

Index                     : 3
Status                    : Ok
Probe Name                : CPU2 Temp
Reading                   : 50.0 C
Minimum Warning Threshold : 8.0 C
Maximum Warning Threshold : 85.0 C
Minimum Failure Threshold : 3.0 C
Maximum Failure Threshold : 90.0 C
  • 各个插槽的电压状态属性
    ./omreport chassis volts
Voltage Probes Information

Health : Ok

Index                     : 0
Status                    : Ok # 状态
Probe Name                : CPU1 VCORE PG # 指标名称
Reading                   : Good #  读取的值
Minimum Warning Threshold : [N/A] # 因为这个电压的状态值只有有值和没有值俩个,所以没有阈值说法
Maximum Warning Threshold : [N/A]
Minimum Failure Threshold : [N/A]
Maximum Failure Threshold : [N/A]
  • 系统版电池状态(纽扣电池)
    ./omreport chassis batteries
Batteries

Health : Ok

Individual Battery Elements
Index      : 0
Status     : Ok
Probe Name : System Board CMOS Battery
Reading    : Good
  • 物理磁盘设备
    ./omreport storage pdisk controller=0
ID                              : 0:1:13 # 设备id
Status                          : Ok # 状态 这个是判断磁盘状态的值
Name                            : Physical Disk 0:1:13 # 物理设备名称
State                           : Online  # 当前的状态
Power Status                    : Spun Up # 电源状态
Bus Protocol                    : SAS # 总线协议
Media                           : HDD 
Part of Cache Pool              : Not Applicable
Remaining Rated Write Endurance : Not Applicable
Failure Predicted               : No
Revision                        : KT37
Driver Version                  : Not Applicable
Model Number                    : Not Applicable
T10 PI Capable                  : No
Certified                       : Yes
Encryption Capable              : No
Encrypted                       : Not Applicable
Progress                        : Not Applicable
Mirror Set ID                   : Not Applicable
Capacity                        : 558.38 GB (599550590976 bytes) # 磁盘大小
Used RAID Disk Space            : 558.38 GB (599550590976 bytes)
Available RAID Disk Space       : 0.00 GB (0 bytes)
Hot Spare                       : No # 是否热备
Vendor ID                       : DELL(tm) # 厂商设备id,这个是要返回出来
Product ID                      : ST600MP0036
Serial No.                      : WAF0E9BK
Part Number                     : CN0FPW68SGW007BU01PNA01
Negotiated Speed                : 12.00 Gbps
Capable Speed                   : 12.00 Gbps
PCIe Negotiated Link Width      : Not Applicable
PCIe Maximum Link Width         : Not Applicable
Sector Size                     : 512B
Device Write Cache              : Not Applicable
Manufacture Day                 : 06
Manufacture Week                : 48
Manufacture Year                : 2017
SAS Address                     : 5000C500A1228CF1
Form Factor                     : Not Available
Sub Vendor                      : Not Available
  • 虚拟磁盘状态
    可以看到这里有俩个阵列,一个是raid1 和raid5
    ./omreport storage vdisk controller=0
List of Virtual Disks on Controller PERC H730 Mini (Embedded)

Controller PERC H730 Mini (Embedded)
ID                                : 0 # 
Status                            : Ok # 整列状态
Name                              : Virtual Disk0
State                             : Ready
Hot Spare Policy violated         : Not Assigned
Encrypted                         : No
Layout                            : RAID-1 # raid级别
Size                              : 278.88 GB (299439751168 bytes) # 整列的大小
T10 Protection Information Status : No
Associated Fluid Cache State      : Not Applicable
Device Name                       : /dev/sda # 在系统里边的设备名称
Bus Protocol                      : SAS
Media                             : HDD
Read Policy                       : Read Ahead
Write Policy                      : Write Back
Cache Policy                      : Not Applicable
Stripe Element Size               : 64 KB # 缓存的条带
Disk Cache Policy                 : Unchanged

ID                                : 1
Status                            : Ok
Name                              : Virtual Disk1
State                             : Ready
Hot Spare Policy violated         : Not Assigned
Encrypted                         : No
Layout                            : RAID-5
Size                              : 6,142.13 GB (6595056500736 bytes)
T10 Protection Information Status : No
Associated Fluid Cache State      : Not Applicable
Device Name                       : /dev/sdb
Bus Protocol                      : SAS
Media                             : HDD
Read Policy                       : Read Ahead
Write Policy                      : Write Back
Cache Policy                      : Not Applicable
Stripe Element Size               : 64 KB
Disk Cache Policy                 : Unchanged
  • 阵列卡信息
    这里只有一块阵列卡
    ./omreport storage controller
Controller  PERC H730 Mini(Embedded)

Controller
ID                                            : 0
Status                                        : Ok
Name                                          : PERC H730 Mini
Slot ID                                       : Embedded
State                                         : Ready
Firmware Version                              : 25.5.3.0005
Minimum Required Firmware Version             : Not Applicable
Driver Version                                : 07.701.17.00-rh1
Minimum Required Driver Version               : Not Applicable
Storport Driver Version                       : Not Applicable
Minimum Required Storport Driver Version      : Not Applicable
Number of Connectors                          : 1
Rebuild Rate                                  : 30%
BGI Rate                                      : 30%
Check Consistency Rate                        : 30%
Reconstruct Rate                              : 30%
Alarm State                                   : Not Applicable
Cluster Mode                                  : Not Applicable
SCSI Initiator ID                             : Not Applicable
Cache Memory Size                             : 1024 MB
Patrol Read Mode                              : Auto
Patrol Read State                             : Stopped
Patrol Read Rate                              : 30%
Patrol Read Iterations                        : 82
Abort Check Consistency on Error              : Disabled
Allow Revertible Hot Spare and Replace Member : Enabled
Load Balance                                  : Not Applicable
Auto Replace Member on Predictive Failure     : Disabled
Redundant Path view                           : Not Applicable
CacheCade Capable                             : Not Applicable
Persistent Hot Spare                          : Disabled
Encryption Capable                            : Yes
Encryption Key Present                        : No
Encryption Mode                               : None
Preserved Cache                               : Not Applicable
Spin Down Unconfigured Drives                 : Disabled
Spin Down Hot Spares                          : Disabled
Spin Down Configured Drives                   : Disabled
Automatic Disk Power Saving (Idle C)          : Disabled
Start Time (HH:MM)                            : Not Applicable
Time Interval for Spin Up (in Hours)          : Not Applicable
T10 Protection Information Capable            : Yes
Current Controller Mode                       : RAID
  • 阵列卡电源状态
    ./omreport storage battery
List of Batteries in the System

Controller PERC H730 Mini (Slot Embedded)
ID                  : 0
Status              : Ok
Name                : Battery
State               : Ready
Recharge Count      : Not Applicable
Max Recharge Count  : Not Applicable
Learn State         : Not Applicable
Next Learn Time     : Not Applicable
Maximum Learn Delay : Not Applicable