solaris查看内存、CUP、硬盘总数和使用情况

时间:2021-11-10 16:20:40

一、内存查询
1,查询总内存
-bash-3.00# prtconf | grep Memory
结果为:
Memory size: 28672 Megabytes
即总内存为 28672M

2,查询剩余内存和总内存
-bash-3.00# echo "::memstat" | mdb -k
结果为:

Page Summary  Pages  MB %Tot
Kernel   111524 871 3%
Anon   296480 2316 8%
Exec and libs   20382 159 1%
Page cache   66403 518 2%
Free (cachelist)   187491 1464 5%
Free (freelist)   2918928 22804 81%
Total   3601208 28134  
Physical   3597230 28103  

即剩余内存为Free (cachelist)+Free (freelist) = 24268M

总内存为Physical=28103M

3,查看剩余内方法2
-bash-3.00# vmstat

结果为:

kthr memory page disk  faults  cpu
r b w swap free re mf pi po fr de sr s2 sd sd -- in sy cs us sy id
0 0 0 54425312 25009768 19 79 39 0 0 0 1 -0 -0 7 0 455 306 226 0 0 100

kthr memory page disk faults cpu
r b w swap free re mf pi po fr de sr s2 sd sd -- in sy cs us sy id
0 0 0 54425312 25009768 19 79 39 0 0 0 1 -0 -0 7 0 455 306 226 0 0 100
即剩余内存为free=25009768kb=24423M

二,查询cpu
1,查询cpu个数
-bash-3.00# mpstat
结果为
CPU minf mjf xcal intr ithr csw icsw migr smtx srw syscl usr sys wt idl
0 22 0 28 27 16 22 0 1 3 0 57 0 0 0 100
1 10 0 25 46 16 34 0 1 3 0 45 0 0 0 100
2 6 0 12 39 13 22 0 1 3 0 34 0 0 0 100
3 22 0 11 212 8 46 0 1 3 0 53 0 0 0 100
返回4行说明有4个cpu

2,查看cpu的主频
-bash-3.00# psrinfo -v
虚拟处理器 0 在下列时间的状态:02/01/2012 09:14:03
自 01/31/2012 17:29:45 开始已在运行。
sparcv9 处理器以 1800 MHz 运行,
而且有 sparcv9 浮点数处理器
虚拟处理器 1 在下列时间的状态:02/01/2012 09:14:03
自 01/31/2012 17:29:45 开始已在运行。
sparcv9 处理器以 1800 MHz 运行,
而且有 sparcv9 浮点数处理器
虚拟处理器 2 在下列时间的状态:02/01/2012 09:14:03
自 01/31/2012 17:29:45 开始已在运行。
sparcv9 处理器以 1800 MHz 运行,
而且有 sparcv9 浮点数处理器
虚拟处理器 3 在下列时间的状态:02/01/2012 09:14:03
自 01/31/2012 17:29:44 开始已在运行。
sparcv9 处理器以 1800 MHz 运行,
而且有 sparcv9 浮点数处理器

3,查看cpu使用率
-bash-3.00# sar -u 3 20
SunOS dsg1 5.10 Generic_141444-09 sun4u 02/01/2012
09:03:15 %usr %sys %wio %idle
09:03:18 0 0 0 100
09:03:21 0 0 0 99
09:03:24 0 0 0 100
09:03:27 0 0 0 100

09:03:15 %usr %sys %wio %idle
09:03:18 0 0 0 100
09:03:21 0 0 0 99
09:03:24 0 0 0 100
09:03:27 0 0 0 100

也可用
-bash-3.00# iostat
tty sd2 ssd0 ssd1 nfs1 cpu
tin tout kps tps serv kps tps serv kps tps serv kps tps serv us sy wt id
0 4 0 0 0 0 0 0 91 7 4 0 0 0 0 0 0 100

三,查看硬盘
1,查看硬盘的大小,转速等性能参数:先找到硬盘的生产商和型号,然后到生产商的网站上查找其性能参数。
-bash-3.00# iostat -E
sd2 Soft Errors: 1 Hard Errors: 0 Transport Errors: 1
Vendor: TSSTcorp Product: CD/DVDW TS-L632D Revision: SR02 Serial No:
Size: 0.00GB <0 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 1 Predictive Failure Analysis: 0
ssd0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST314655FSUN146G Revision: 0691 Serial No: 0746S2WHHZ
Size: 146.81GB <146810536448 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
ssd1 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: SEAGATE Product: ST314655FSUN146G Revision: 0691 Serial No: 0745S2P7A7
Size: 146.81GB <146810536448 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
即有两个硬盘ssd0和ssd1大小都是146.81GB

2,查看硬盘使用情况
-bash-3.00$ df -h

文件系统 大小 用了 可用 容量 挂接在
/dev/dsk/c1t0d0s0 102G 93G 7.6G 93% /
swap 52G 1.6M 52G 1% /etc/svc/volatile