树莓派3 B+ 读取温湿度传感器DHT11

时间:2021-02-17 04:40:19
# encoding=utf-8

# power by : FUNCO_小风

import RPi.GPIO as GPIO
import time

# 延时函数
def delay(i):
while i:
i -= 1

# 初始化dht11连接引脚
# dht11_pin - dht11连接的引脚号
def init_dht11(dht11_pin):
# 输出模式 初始状态给高电平
GPIO.setup(dht11_pin, GPIO.OUT)
GPIO.output(dht11_pin, 1)

# 用于获取
# dht11_pin - dht11连接的引脚号
# 返回二元组 [ 湿度 , 温度 ]
def get_dht11(dht11_pin):
buff=[0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0]

GPIO.output(dht11_pin,0)
time.sleep(0.02) # 拉低20ms

GPIO.output(dht11_pin,1)

GPIO.setup(dht11_pin,GPIO.IN) # 这里需要拉高20-40us,但更改模式需要50us,因此不调用延时


while not GPIO.input(dht11_pin): # 检测返回信号 检测到启示信号的高电平结束
pass


while GPIO.input(dht11_pin): # 检测到启示信号的高电平则循环
pass

i=40

while i:
start=time.time()*1000000 # 为了严格时序 循环开始便计时
i-=1
while not GPIO.input(dht11_pin):
pass
while GPIO.input(dht11_pin):
pass
buff[i]=time.time()*1000000-start# 为了严格时序 每次测得数据后都不马上处理 先存储


GPIO.setup(dht11_pin,GPIO.OUT) # 读取结束 复位引脚
GPIO.output(dht11_pin,1)

# print "buff - ",buff

# 开始处理数据
for i in range(len(buff)): # 将时间转换为 0 1
if buff[i]>100: # 上方测试时是测试整个位的时间
# 因此是与100比较 大于100为1(位周期中 低电平50us)
buff[i]=1
else:
buff[i]=0
# print "After - ",buff


i=40
hum_int=0
while i>32: # 湿度整数部分
i-=1
hum_int<<=1
hum_int+=buff[i]
# print "hum - ",hum_int

tmp_int=0
i=24
while i>16: # 温度整数部分
i-=1
tmp_int<<=1
tmp_int+=buff[i]
# print "tmp - ",tmp_int
return [hum_int,tmp_int]

GPIO.setmode(GPIO.BOARD)
init_dht11(7)
print get_dht11(7)
GPIO.cleanup()

# 注意
# 若非连续测量 可以不延时 但连续测量时建议每次测量间间隔0.2s以上再调用get_dht11(dht11_pin)获取数据(树莓派不稳定)
# DHT11虽然有40位 实际温度和湿度的小数部分读数总为0
# 如果程序无法正常读取,可以考虑是否起始部分的延时不准确,可以参考注释以及实际环境的测量结果调整延时
# 程序测试环境为 $树莓派3代B+$ $python2.7.9 $Raspbian GNU/Linux 8$